Ventilator Zisline JV100

3280000,00
The Zisline JV100 is designed for controlled jet ventilation in adults and children weighing 15 kg or more.

The device operates in three primary modes:
  • Injection mode
  • Non-injection mode
  • Catheter mode

Type: Ventilator

Country of origin: Russia

Brand: Triton

Description
Specifications

Description

The Zisline JV100 is a compact and reliable device designed for emergency and short-term respiratory support in adult patients. It is especially effective during resuscitation, patient transport, and in space-constrained environments such as ambulances or operating rooms.
The JV100 operates in three primary modes:
  • Injection mode
  • Non-injection mode
  • Catheter mode
This flexibility allows therapy to be tailored to the specific clinical situation. The device provides precise control over ventilation parameters and oxygen concentration in the inspired gas mixture (21% to 100%), as well as airway pressure monitoring.
Despite its compact size, the JV100 features an advanced digital monitoring system, including capnography (EtCO₂/FiCO₂) and real-time airway pressure waveform display, enhancing both safety and efficacy of ventilation.
Power is supplied from 220 V mains or an integrated battery, which provides up to 6 hours of typical operation and guarantees at least 60 minutes of continuous operation in emergency mode—a critical feature during transport or power outages.

Specifications

Ventilation Modes
  • Injection
  • Non-injection
  • Catheter
Ventilation Parameters
  • Minute ventilation (MV):
  • – Injection / Non-injection modes: 5–30 L/min
  • – Catheter mode: 3–20 L/min
  • Inspiratory/Expiratory ratio (I:E):
  • – Injection / Non-injection: 1:3, 1:2, 1:1, 3:2, 2:1
  • – Catheter: 1:3, 1:2, 1:1
  • Respiratory rate (RR): 30–300 breaths/min
  • Maximum pressure (Pmax): 10–60 cm H₂O
  • FiO₂ (in non-injection and catheter modes): 21–100%
  • Endotracheal tube diameter: 5–10 mm
Digital Monitoring (Real-Time)
  • Minute ventilation (MV)
  • Positive End-Expiratory Pressure (PEEP)
  • Mean airway pressure (Pmean)
  • Peak Inspiratory Pressure (PIP)
  • Inspiratory volume (Vinsp)
  • CO₂ concentration: EtCO₂, FiCO₂
  • Airway pressure waveform (Paw)
  • Capnogram (PCO₂)
Power Supply and Autonomy
  • Mains power: 220 ± 22 V, 50 Hz
  • Battery:
  • – Guaranteed operation: 60 minutes
  • – Typical runtime (new battery): up to 6 hours
Advantages
  • Three ventilation modes for flexibility in emergency scenarios
  • Adjustable FiO₂ from 21% to 100%
  • Advanced digital monitoring with integrated capnography
  • Real-time pressure and volume control
  • Up to 6 hours of battery operation — ideal for transport
  • Compact and reliable — suitable for EMS, ICU, and operating rooms
  • Meets modern resuscitation standards